| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | InputRange | Output | Isolation | ResponseTime | Accuracy | Voltage-Supply | MountingType | TerminationStyle | OperatingTemperature | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
                 
                   
                
                 | 
				
                    DCSA20TRANSDUCER CURRENT 10-30VDC  |  
                2,537 | 142.54 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | DCSA | Active | Current Transducer | 0 ~ 20mA | 4 ~ 20mA, 1 ~ 10VDC | Not Isolated | 300ms | ±0.25% | 10 ~ 30VDC | DIN Rail | Screw Terminal | -30°C ~ 60°C | 
                 
                   
                
                 | 
				
                    DCSA5TRANSDUCER CURRENT 10-30VDC  |  
                2,522 | 142.54 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | DCSA | Active | Current Transducer | 0 ~ 5mA | 4 ~ 20mA, 1 ~ 10VDC | Not Isolated | 300ms | ±0.25% | 10 ~ 30VDC | DIN Rail | Screw Terminal | -30°C ~ 60°C | 
                 
                   
                
                 | 
				
                    286-661CURRENT FLOW MONITORING MODULE A  |  
                2,998 | 144.71 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Box | - | Active | Current Transducer | 13 ~ 460mV | 0.08 ~ 6A | - | 40ms | - | 24VDC | Socketable | Plug In | -25°C ~ 40°C | 
                 
                   
                
                 | 
				
                    286-664CURRENT FLOW MONITORING MODULE A  |  
                3,425 | 149.42 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Box | - | Active | Current Transducer | 44 ~ 430mV | 0.2 ~ 3A | - | 300ms | - | 24VDC | Socketable | Plug In | -25°C ~ 40°C | 
                 
                   
                
                 | 
				
                    286-665CURRENT FLOW MONITORING MODULE A  |  
                2,129 | 149.42 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Box | - | Active | Current Transducer | 23 ~ 850mV | 1 ~ 10A | - | 200ms | - | 24VDC | Socketable | Plug In | -25°C ~ 40°C | 
                 
                   
                
                 | 
				
                    CR4810-250TRANSDUCER VOLTAGE 24VDC  |  
                2,372 | 150.42 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Box | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 250VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    CR4810-150TRANSDUCER VOLTAGE 24VDC  |  
                3,475 | 150.42 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 150VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    CR4810-500TRANSDUCER VOLTAGE 24VDC  |  
                2,255 | 150.42 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 500VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    CR4810-50TRANSDUCER VOLTAGE 24VDC  |  
                2,853 | 150.42 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 50VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    TCSA20TRANSDUCER CURRENT 10-30VDC  |  
                3,500 | 151.67 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | TCSA | Active | Current Transducer | 0 ~ 20A | 4 ~ 20mA | - | 300ms | ±0.25% | 10 ~ 30VDC | Chassis Mount | Quick Connect - 0.250 (6.3mm) | -30°C ~ 60°C | 
                 
                   
                
                 | 
				
                    TCSA50TRANSDUCER CURRENT 10-30VDC  |  
                2,939 | 151.67 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | TCSA | Active | Current Transducer | 0 ~ 50A | 4 ~ 20mA | - | 300ms | ±0.25% | 10 ~ 30VDC | Chassis Mount | Quick Connect - 0.250 (6.3mm) | -30°C ~ 60°C | 
                 
                   
                
                 | 
				
                    CR4820-150TRANSDUCER VOLTAGE 24VDC  |  
                2,197 | 161.98 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 150VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    CR4820-250TRANSDUCER VOLTAGE 24VDC  |  
                2,169 | 161.98 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 250VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    CR4820-50TRANSDUCER VOLTAGE 24VDC  |  
                2,253 | 161.98 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 50VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    CR4820-500TRANSDUCER VOLTAGE 24VDC  |  
                2,756 | 161.98 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 500VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    CR4820-20TRANSDUCER VOLTAGE 24VDC  |  
                3,024 | 172.78 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Box | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 20VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    CR4820-600TRANSDUCER VOLTAGE 24VDC  |  
                2,850 | 172.78 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 600VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | 
                 
                   
                
                 | 
				
                    ISOBLOCK I-FG-1C (50A 5V)TRANSDUCER CURRENT 9-28VDC  |  
                3,181 | 180.68 | 
                
                    RFQ | 
               
                
                  
                    
                
                     Datasheet  | 
				 
                Box | IsoBlock I-FG | Active | Current Transducer | 0 ~ 50A | ±5V | 1200V (Working) | 5µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Screw Terminal, Spring Terminal | -25°C ~ 70°C | 
                 
                   
                
                 | 
				
                    ISOBLOCK I-FG-1C (25A 5V)TRANSDUCER CURRENT 9-28VDC  |  
                3,351 | 180.68 | 
                
                    RFQ | 
               
                
                  
                    
                
                     Datasheet  | 
				 
                Box | IsoBlock I-FG | Active | Current Transducer | 0 ~ 25A | ±5V | 1200V (Working) | 5µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | 
                 
                   
                
                 | 
				
                    CR4640-150TRANSDUCER VOLTAGE 24VDC  |  
                3,215 | 183.43 | 
                
                    RFQ | 
               
                
                  
                    
                 
                     Datasheet  | 
				 
                Box | CR4600 | Active | Average RMS AC Voltage Transducer | 0 ~ 150VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C |